2.99 See Answer

Question: Refer to the constant-head arrangement shown


Refer to the constant-head arrangement shown in Figure 7.5. For a test, the following are given:
L = 450 mm
A = area of the specimen = 23 cm2
Constant-head difference = h = 700 mm
Water collected in 3 min = 350 cm3
Calculate the hydraulic conductivity (cm/s).

2.99

See Answer